Global Z-score Normalization Enables Training-free Automatic Detection of Punctate White Matter Lesions in Neonates
PDF

Keywords

Neonates
Punctate white matter lesions
Auto-segmentation
Magnetic resonance imaging

How to Cite

Wat, H. C., Xu, K., Zhang, E., & Lodygensky, G. (2026). Global Z-score Normalization Enables Training-free Automatic Detection of Punctate White Matter Lesions in Neonates. McGill Science Undergraduate Research Journal, 21(2). https://doi.org/10.26443/msurj.v21i2.506

Abstract

Punctate white matter lesions (PWMLs) are common in preterm neonates and linked to adverse neurodevelopmental outcomes. Conventional identification relies on subjective visual contrast on MRI. We propose a global, training-free z-score normalization framework for automatic PWML detection, enabling standardized, interpretable segmentation across modalities without machine learning or subject-specific calibration. We analyzed 44 neonates from the dHCP dataset, comprising 1069 axial slices from T1w, T2w, and mean diffusivity (MD) maps. Reference masks were generated by consensus among four trained raters. Slices within each modality were standardized to a global z-score space, allowing comparable intensity distributions. For each modality, a detection threshold of z-score was swept from -3 to 3 standard deviations to construct receiver operating characteristic (ROC) curves. Lesion–white matter contrast ratios (CR) were also computed. Inter-rater reliability (Cohen’s k) reached 0.88 for T1w, 0.77 for T2w, and 0.73 for MD. PWML–white matter contrast differences were statistically significant (p < 0.01). Contrast magnitude was greatest for T1w (CR = 0.57 ± 0.19), compared to T2w (-0.18 ± 0.08) and MD (-0.14 ± 0.12). ROC analysis revealed that T1w outperformed the other modalities, achieving an AUC of 0.98 at an optimal threshold of 0.84 (True Positive Rate = 0.90, False Positive Rate = 0.06). In contrast, T2w and MD achieved lower AUCs of 0.84 and 0.67, respectively. Global z-score normalization yields a robust, fully automatic lesion detection method. This interpretable baseline achieves high sensitivity with minimal false positives and provides a reproducible benchmark for evaluating deep-learning or quantitative MRI pipelines.

https://doi.org/10.26443/msurj.v21i2.506
PDF
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright (c) 2026 Hoi Ching Wat, Kylie Xu, Erjun Zhang, Gregory Lodygensky

Downloads

Download data is not yet available.